>

Synthes pelvic inventory - INVENTORY CONTROL FORM 2.4 mm LCP ® Distal Radius Plate System 2.4 mm Locking Screw

Pelvic calcification is the accumulation of calcium deposits in the lower a

SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Screws Patient Information: J2278-F 6/10 Inventory Control Form Small Fragment DCP and LC-DCP (Stainless Steel) 3 LENGTH LENGTH 204.010 10 mm 204.012 12 mm 204.014 14 mm 204.016 16 mm 204.018 18 mm 204.020 20 mm 204.022 22 ...The EMAX™ 2 Plus System is the ultimate high-powered, lightweight 1,2, small bone cutting system. Designed for surgeon comfort, this lightweight 1,2 device gives surgeons the flexibility 1,3,7, power, and low noise they need for long, complex neurosurgery and spinal procedures. MIDAS REX MR7 High-Speed Drill System (Medtronic)Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the …Synthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Note: For recognized manufacturer, refer to the product label. www.depuysynthes.com Synthes …MatrixNEURO™ System. The MatrixNEURO™ System features regular (0.5 mm profile) and Ultra Low Profile (0.4 mm profile) implants. In addition, a variety of mesh options are available including various shapes and sizes, as well as contourable, reconstruction, and pre-formed. 1-3. Get In Touch with a Sales Consultant.Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the …Instrument set designed for the tissue-sparing anterior approach to total hip replacement. Facilitates the Anterior Smith-Petersen approach, enables acetabular and femoral exposure. Catalog #. Description. 37-4106. Blunted Serrated Cobra (2) 2598-07-200. MI 2-Incision Sharp Cobra (Serrated Point) 2598-07-260.The Titanium Sternal Fixation System provides internal fixation of the sternum for primary or secondary closure and repair. 1,2. Get in Touch with a Sales Consultant.Universal Small Fragment System System Catalog DePuy Synthes 12 Instruments Core System Trays Anatomic Implant Trays Case & Lid Options Set Information Instruments (Continued) SKU Description 03.133.175 2.5 mm Hex Driver Shaft, Self-Retaining Length 100 mm with Quick Coupling 03.133.200 Plate Bending Iron Closed for 2.7/3.5 mm Plates66 DePuy Synthes Pelvic Implants and Instruments Surgical Technique Trocar for Cannulated Screws 6.5 and 7.3 mm The trocar for 6.5 mm / 7.3 mm cannulated screws is in- tended to be used as a drill sleeve for a 2.8 mm guide wire and as a reduction tool, especially in minimally invasive ­procedures.Fractures of the pubic ramus are among the most common pelvic fracture types and a demanding need for their improved management has been reported [].There is a strong body of evidence regarding timing and choice of surgical approach for the posterior pelvic ring [2,3,4]; however, when addressing traumatic of the anterior pelvic ring, particularly the pubic branches, conclusions in the ...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactThe recently introduced implant FNS (DePuy Synthes, Zuchwil, Switzerland) (Fig. (Fig.1) 1) was developed for the dynamic fixation of FNFs. The FNS includes three parts: an ARScrew, a bolt, and a plate. The plate provides angular stability (a fixed angle between the bolt and the ARScrew).Fig 1: Acetabular plate in the small, extended version shown on a bone model with fracture pattern (black) and screw trajectories (gray). Due to demographics and an increasingly aging population, pelvic fractures are becoming highly relevant for society and the healthcare system. Moreover, with a shift from nonoperative to operative treatment ...This site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.If you have a specific Medical Information Request, please use the following web form Medical Information Request instead of the below, so that your request can be directly managed by our Medical Affairs team. Contact UK Customer Services (+44 113 387 7800) Order products with J&J Customer Connect. The DePuy Synthes UK customer support team is ...About This Product. The system consists of three plate types, each one available in left and right version: Lateral Plate. Shaft Plate. Medial Plate. The VA LCP Clavicle Plates are made up of stainless steel and titanium alloy. The holes of the plates accept 2.7 mm cortex screws, 2.7 mm VA locking screws and 2.7 mm metaphyseal compression screws.Page 63 Miss-A-Nail Locking (continued) Insert the second screw using the same technique. Insert the nail Proceed with standard nail insertion technique (pages 21-25). Insert the second screw Drill for shaft screw Insert the 3.2 mm calibrated Insert the 5.0 mm guide wire through the sleeve shaft screw and into the femoral head until it is ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 …The Femoral Recon Nail System is an integrated nailing system designed to adapt to multiple surgical approaches. The FRN System provides the choice of Greater Trochanter (GT) and Piriformis Fossa (PF) entry points and anatomical nail designs to support surgical preferences and facilitate hospital standardization. Contact Us.61.503.830, 03.503.034, 03.503.036... View More. PRODUCT CODES. DESCRIPTION. The MatrixMANDIBLE™ Plating System provides internal fixation solutions for mandible trauma and reconstruction procedures. It includes a wide selection of mandible plates and screws. Plates, screws and instruments are color-coded. Get in Touch with a Sales Consultant.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...MatrixNEURO™ System. The MatrixNEURO™ System features regular (0.5 mm profile) and Ultra Low Profile (0.4 mm profile) implants. In addition, a variety of mesh options are available including various shapes and sizes, as well as contourable, reconstruction, and pre-formed. 1-3. Get In Touch with a Sales Consultant.02.226.010, 02.226.011, 02.226.012... View More. PRODUCT CODES. DESCRIPTION. DePuy Synthes Headless Compression screws are available in a range of sizes from 1-5-6.5 mm. They are self-drilling and self-tapping, allowing surgeons to control compression during fixation procedures. Get in Touch with a Sales Consultant.Additionally, with our services, all of the info you contain in your Synthes Modular Hand Inventory Control Form the well-protected against leakage or damage through cutting-edge encryption. A system manufactured of an extensive range of basis and specialty plates for fracture repair and deformity correction designed for lateral and dorsal ...The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who hasInventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. SS/VALCPCC/ICF/V2 04/22 Page 1 of 2 To order (USA): 800-523-0322Synthes 13 Sterilization Parameters for Set (115.700) This Synthes set with all additionally available items, as marked in the case, can be sterilized by the following parameters. For more information, please refer to graphic case package insert. Method Cycle Temperature Exposure Time Steam Prevacuum 132°-135°C 8 Minutes (Wrapped) (270 ...The modular set for pelvic implants. The design of the plates has been modified to allow easier contouring to the patients anatomy, together with optimized screw hole geometry for a wider range of angulations. The completely redesigned pelvic C-clamp comes in a set for emergency pelvic stabilization ready to use out of the box. A new Modular ...DCPTM and LC-DCPTM Systems - synthes.vo.llnwd.netInventory Control Form Date: Hospital: Titanium MatrixORTHOGNATHIC 1.85 mm Titanium Matrix Screws, self-drilling (dark purple) (1/pkg) 04.511.224.05 4 mm ... DEPUY SYNTHES CANADA To order: (800) 668-1119. Plates (cont'd) Titanium MatrixORTHOGNATHIC J9341-D 4/13 Inventory Control FormInstrument set designed for the tissue-sparing anterior approach to total hip replacement. Facilitates the Anterior Smith-Petersen approach, enables acetabular and femoral exposure. Catalog #. Description. 37-4106. Blunted Serrated Cobra (2) 2598-07-200. MI 2-Incision Sharp Cobra (Serrated Point) 2598-07-260.6 DePuy Synthes Large Distractor–Femur Surgical Technique Universal Joint Assembly 1 Select a 14.0 mm threaded spindle (A) of appropriate length (most likely 480 mm). A transverse hole will be in the proximal end when applied to the femur. 2 Turn the end piece with double joint (B) onto the threadedProduct Information. Essential equipment for the surgical treatment of pelvic and acetabular fractures. The complex anatomy of the pelvic ring and acetabulum involve complex surgical exposures and demands exact anatomical reduction to achieve positive functional results.For that reason, the airSlate SignNow online application is a must-have for filling out and putting your signature on synthes pelvic inventory on the go. Within seconds, receive an e- document with a legally-binding signature. Get synthes ex fix inventory signed straight from your smartphone using these 6 steps:Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction ...Product Codes : 03.010.127, 03.010.048, 04.003.240S... View More. PRODUCT CODES. DESCRIPTION. The EXPERT™ Cannulated Lateral Entry Femoral Recon Nail is designed to facilitate a lateral trochanteric entry site in the greater trochanter, providing ease of access while reducing the chance of varus deformity. Product Specifications.2 DePuy Synthes Spring Plates 3.5 Surgical Technique Description In­pelvic­and­acetabular­surgery,­it­is­often­difficult­to­reduce­ and­fix­small­bone­fragments.­The­Spring­Plates­3.5­are­in-tended­to­reduce­and­stabilize­bone­fragments­that­are­too­ …Click on New Document and choose the file importing option: add Synthes large fragment set inventory sheet from your device, the cloud, or a protected URL. Make adjustments to the template. Utilize the top and left panel tools to modify Synthes large fragment set inventory sheet.Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes "Import-ant ...Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°2.Create a template of the proximal femur on the AP pelvic x-ray, rotate this template around the center of the femoral head until you have a satisfactory containment. x Assess the correction that will achieve coverage (3) x Choose a target neck/shaft angle based on patient pathology (4) Calculate the correction angle: The angle betweenThe 2.7mm VA LCP™ Clavicle Hook Plate System provides solutions for lateral clavicle fractures with associated acromioclavicular and coracoclavicular ligament injuries and isolated ligamentous injuries. The Clavicle Hook Plates have enhanced hook depths and angulations based on an extensive analysis of shoulder morphology. 1,2 *.Object Moved This document may be found hereInventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESWhen it comes to purchasing a used truck, finding a reliable dealer with a vast inventory is crucial. One name that stands out in the trucking industry is Lone Mountain Truck Inven...Double/Triple Pelvic Osteotomy Plates Surgical Technique DePuy Synthes 1 Screw Holes The DePuy Synthes Vet DPO/TPO plate is designed with two distinct screw-hole technologies to accommodate all plating modalities. The plate includes three stacked Combi™ holes on the caudal side, and three stackedInventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.ITS pelvic reconstruction system, pure titanium ASTM F 136). The Matta Stryker pelvic plates offer annealed or nonannealed versions depending on the desired construct stiffness. If a less stiff construct is required such as in an ilium fracture or a posterior wall fracture, the annealed MPS flex plate can be used. Plate Designs and FunctionThe Synthes Large External Fixation System is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: - Stabilization of soft tissues and fractures - Polytrauma/multiple orthopaedic trauma - Vertically stable pelvic fractures, or as a treatment adjunctSynthes Pelvic Implant Set With Self-Tapping Screws (125.885) Plates 3.5 mm Reconstruction Plates Catalog # Description 245.15 5 Holes (2) ... 306.20 Pelvic Implant Set Graphic Case Catalog # 218.0 Screws 3.5 mm Self-Tapping Screws Catalog # Description 55 55 mm (3) 60 60 mm (3) 65 65 mm (3) 204.670 70 mm (3)Our Trauma & Extremities portfolio offers comprehensive solutions for the treatment of fractures, deformities, and other orthopaedic traumas. Our wide range of surgical instruments and fixation products are designed to provide solutions tailored to the diverse needs of orthopaedic professionals and patients. Get In Touch With a Sales Consultant.Orthopaedic Cable System. The DePuy Synthes Cable System is a cerclage system that consists of two different-sized cerclage cables with crimp in three different materials [Stainless steel, Titanium Alloy, Cobalt Chromium Alloy], and instruments for applying the cable assembly. Product Specifications.synthes.vo.llnwd.netSynthes Screw Reference Chart Reference Chart Screws, Drill Bits, Taps and Guide Wires. Locking Screws, Guide Wires, Drill Bits and Taps ... SCREW DIAMETER (mm) Thread Diameter 1.0 1.3 1.5 2.0 2.4 2.7 3.5 4.0 4.5 6.5 Cortex, self-tapping Cortex Pelvic Shaft Cortex Cancellous Cortex Shaft Malleolar Cancellous and Non- and Non- and Non-Make these fast steps to modify the PDF Synthes small frag inventory online free of charge: Register and log in to your account. Log in to the editor with your credentials or click on Create free account to evaluate the tool’s functionality. Add the Synthes small frag inventory for redacting. Click the New Document button above, then drag and ...The Pelvic C-Clamp is comprised of rails and arms with a locking mechanism. This allows a linear movement of the arms. The Pelvic C-Clamp should always be used in combination with the designated cannulated nails. Overview • Permits compression and stabilization of fractures or luxations of pelvic ring.DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications.Now that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c...2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology with conventional plating techniques. The LCP Proximal Tibial Plate 3.5 has a limited-contact profile. The head and neck portions of the plate accept 3.5 mmindiquées dans la notice « Informations importantes » de Synthes. Traitement/reconditionnement du dispositif Les instructions de traitement des implants et de reconditionnement des boîtes, plateaux d'instruments et dispositifs réutilisables sont détaillées dans la brochure Synthes « Informations importantes ».Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the …Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 mm 04.043.035S 345 mmAccording to the NAHB report for March, builders remained cautiously optimistic in April as limited resale inventory helped to increase demand in the new home market. According to ...State. Zip code. 1. PRO-WP-1. Focusing on the instrumentation surrounding exposure and reduction for pelvis and acetabulum fractures, PRO Pelvis plating system is uniquely designed to facilitate the Anterior Intrapelvic Approach (AIP), where working in the deep, narrow space in the pelvis poses special surgical challenges.Click on New Document and choose the file importing option: add Synthes large fragment set inventory sheet from your device, the cloud, or a protected URL. Make adjustments to the template. Utilize the top and left panel tools to modify Synthes large fragment set inventory sheet.Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESInventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9001-D 10/10 3.5 mm LCP Superior Anterior Clavicle Plates, with Lateral Extension 3.5 mm LCP Superior Anterior Clavicle Plates HOLES HOLESSynthes USA, LLC 1101 Synthes Avenue Monument, CO 80132 Manufactured or distributed by: Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322 To order (Canada): 844-243-4321 Note: For recognized manufacturer, refer to the product label. www.depuysynthes.com Synthes GmbH Luzernstrasse 21 4528 ...DePuy Synthes Alyssa Bryan Regulatory Affairs Specialist I 1301 Goshen Parkway West Chester, Pennsylvania 19380 ... Synthes 3.5 mm Low Profile Pelvic Reconstruction Plate K031573 • 3.5 mm Low Profile Reconstruction Plates • 3.5 mm Low Profile Curved Reconstruction Plates (radius 108 mm)Large External Fixation System. The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.External Fixator Devices include pins, wires, rods and clamps to form a frame for the reposition and fixation of bone fragments. Pins and wires are single-use im-plants and build the connection of the frame to the bone(s). Rods and clamps are the parts of the frame that are located outside of the body and are designed for multiple usages.Inventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42–60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.The FIBULINK Syndesmosis Repair System is available in stainless steel and titanium. It can be used in combination with a fibula plate. The system is compatible with the following DePuy Synthes plate holes: 1/3 tubular plate holes (LCP and non-locking) Non-threaded portion of a combi hole in a 2.7 mm/3.5 mm LCP Distal Fibula PlateInventory Control Form Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada Please contact your sales consultant for items approved for sale in Canada. *2.4 mm Cortex Screws in lengths 42-60 mm are available in the 2.4/2.7 mm VA-LCP Forefoot/Midfoot Plating System.DESIGN EVIDENCE References: 1. DePuy Synthes Trauma, TFNA Pre/Post Fatigue Sliding Data Analysis. July 14, 2015. MT15-273. 2. Galal S, Nagy M. Non-parallel screw fixation for femoral neck fractures in young adults. Journal of Clinical Orthopaedics and Trauma. 8 (2017) 220-224.The Synthes Large External Fixation Systems is intended to provide treatment for long bone and pelvic fractures that require external fixation. Specifically, the components can be used for: • Stabilization of soft tissues and fractures • Polytrauma/multiple orthopaedic trauma • Vertically stable pelvic fractures, or as a treatment adjunctsynthes.vo.llnwd.netThis site is published by the DePuy Synthes Companies, which are solely responsible for its content. This site is intended for use by residents of Latin America, Europe, Middle East and Africa, Asia & Pacific only.4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.DESCRIPTION. The Collinear Reduction Clamp features a sliding mechanism that accepts different attachment arms to create a versatile reduction tool that adapts to your clinical needs. The arms can be mounted in four positions to accommodate long bone, articular, and pelvic fractures. Get in Touch with a Sales Consultant.The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.Inventory Control Form 4.5 MM CANNULATED SCREW SYSTEM PLUS (CSS+) 4.5 mm Cannulated Screw System + Length Short Thread Part Number Length Long Thread Part Number Length Full Thread Part Number 20 mm 04.353.520 N/A 20 mm 04.355.520 22 mm 04.353.522 N/A 22 mm 04.355.522 24 mm 04.353.524 N/A 24 mm 04.355.524 26 mm 04.353.526 N/A 26 mm 04.355.526The DePuy Synthes Large External Fixation Systems are intended to provide treatment for l, The DePuy Synthes Cannulated Compression Headless Screws are, Inventory Control Form LCP Clavicle Plate System Synthes (USA) Synthes (Canada) Ltd. To Order: (800) , PRODUCT CODES. DESCRIPTION. The Orthopaedic Cable Syst, Follow this step-by-step guide to build your Mod hand inventory: Open the pref, Synthes Pelvic Reduction Forceps w/ Speed Lock, X-Large Synthes Holding Forceps with Foot Synthes Speed Lock Reduc, 398.55 - Synthes Blunt Pelvic Retractor (Each) REF: 3, The LCP™ Proximal Femur Plate (4.5 mm) is part of the De, J5294-F 10/12 These implants and instruments are available nonsterile, Pelvic Implants and Instruments • Surgical Technique 11, by the AO and DePuy Synthes and belong still to sur - geo, Our Trauma & Extremities portfolio offers comprehensive solution, Synthes Surgical Pelvic Reduction Forceps 398.88 $ 375, Consult Depuy Synthes's entire Low Profile Pelvic System c, Inventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate Sy, Midfoot Fusion Bolt (6.5 mm) Product Codes : 02.111.150, 02.11, External Fixator Devices include pins, wires, rods and , Inventory Control Form 2.7 mm Variable Angle LCP® Clavicle P.