Ul u373 - 5 thg 12, 2019 ... I do have Georgia Pacific manual open which shows configuration B UL U373 and WHI GP

Title: BXUV.U423 - Fire-resistance Ratings - ANSI/UL 263 Author: dmartinez Created D

Standard UL 263 shall be permitted to be used to determine the hourly fire endurance rating of walls and floors with control joints. 1.11 Tests for determining the surface burning characteristics of building materials, based on the rate of flame spread, are found in the Standard for Test for Surface Burning Characteristics of Building Materials ...literature.puertoricosupplier.com UL V473 1 hour Shaftwall. 9. Fire tests were conducted without back blocking of shaftliner joints. Install factory cut edges back to back for all WHI designs and UL 1 hour V473. *10. For WHI GP/WA 120-01 finished 2 hour one side, install the base layer of 1/2” (12.7 mm) ToughRock® Fireguard C® gypsumMô tả . Cần cẩu thuỷ lực nhãn hiệu UNIC model URV343 là sản phẩm được nhập khẩu từ Nhật Bản có thiết kế 3 đốt sản xuất theo dòng “V-series” có xuất xứ từ Nhật Bản, sức …Oct 29, 2019 · UL Product iQ Overview. UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U.S., Canada and the rest of the world. The intuitive guided keyword search allows you to search by almost any criteria in one field. UL Design No. W454 (National Gypsum Co.) (2) Layers of 1” thick gypsum board liner panels fit into H-Studs w/ (1) layer of 5/8” thick gypsum board on each side of wall assembly. Standard 2-1/2” long Aluminum Breakaway Clips can be used to secure assembly. 3 Hour UL Assemblies: W454 (1-3/8” flange) 3 hour; W467 (1-3/8” flange) 3 hourQ: Can you explain the concept behind the wall assemblies described by UL Fire Resistance Wall Design Nos. U336, U347, U366, U373, U375 and U388? A: This series of designs is intended for use as townhouse or duplex separations as required by Sections R302.2.2 and R302.3 of the 2018 International Residential Code (IRC), and as a fire wall when ...Have a Question About Assemblies? Call: 1-800-USG-4YOU. Contact Technical Support. The world's most comprehensive collection of sound-tested, fire-rated assemblies.Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United S tates Design Criteria and Allowable Variancesinstallation and use of UL Certified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. Assemblies such as UL U336 have an option for a single wood-frame wall supporting a double shaftliner gypsum membrane. A second wood wall could be used on the other side of the double gypsum membrane to support floor framing (i.e., stair and landing framing).– UL/ULC Classified for fire resistance (type SLX) – Panels are 1 thick and 24 wide with beveled edges and are available in 8 -12 lengths – Refer to product submittal sheet …TECHNICAL GUIDESHAFTLINER FOR AREA SEPARATION WALLSDensGlass Shaftliner Area Separation WallsFor latest information and updates: Technical Service Hotline 1.800.225.6119…UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U.S., Canada and the rest of the world. The intuitive guided keyword search allows you to search by almost any criteria in one field. Search by UL file number, product type, CCN (category code), fire-resistive design or ...Oct 29, 2019 · UL Product iQ Overview. UL Product iQ offers the best of UL’s Online Certifications Directory and UL Product Spec, all in a single database for the U.S., Canada and the rest of the world. The intuitive guided keyword search allows you to search by almost any criteria in one field. BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ...24 Jul 1943. Atlantic, west of the Madeira Isles: U-373 was attacked by Avenger and Wildcat aircraft from the US escort carrier USS Santee. The boat was ...(15.9 mm) DensGlass® Fireguard® Sheathing is included in a variety of UL and ULC listings and other designs in the GA-600 Fire Resistance Design Manual. Superior Weather Protection DensGlass Sheathing integrates a water-resistant, treated core with a fiberglass mat face and back to provide superb protection from the elements.UL U356 Assembly as Defined, in Minutes UL U356 for a lis Exterior manufacturersSide Min SPF " Fire Rated Thermo-Ply® Red or Blue attached to studs then assembly siding types applied One-hour rated assembly fire endurance from interior side only See ting of of 5/ 8 GWB that can be applied to achieve a Finish Rating of 20.4 minutes or greater asMô tả . Cần cẩu thuỷ lực nhãn hiệu UNIC model URV343 là sản phẩm được nhập khẩu từ Nhật Bản có thiết kế 3 đốt sản xuất theo dòng "V-series" có xuất xứ từ Nhật Bản, sức nâng lớn nhất theo thiết kế 3030 tại tầm với 2,7 m, là dòng sản phẩm cẩu dành cho xe tải hạng trung với tải trọng 6-11 tấn.specify use of a UL Classified ceiling damper. UL 555C investigations Ceiling dampers are investigated either as part of the fire-resis-tance-rated floor-ceiling or roof-ceiling assembly or in accordance with requirements in UL 555C, the Standard for Safety for Ceiling Dampers. This standard includes requirements and methods ofIn today’s highly competitive marketplace, it is crucial for businesses to prioritize the safety and compliance of their products. One way to achieve this is through UL testing services.Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission.You have been logged out. You have been logged out due to inactivityThey want to use U373 for the rated wall. It is a 2 hr rated wall assembly for load bearing. They want to use configuration B which is shown in section as: 1/2" drywall. …FireDefender® Fireguard ForceField® Ply-Bead® PlyFrame® Plytanium® Southern Yellow Pine Lumber TemStock® Thermostat® ToughRock® UltraStock® Areas of Application …UL Design U373 Area Separation Wall assembly was evaluated at a height up to 44’ (13,411 mm) and the ITS/WHI GP/WA 120-04 Area Separation Wall assembly was evaluated at a height up to 68’ (20,726 mm). To view installation video, visit http://www.gpgypsum.com (DensGlass Shaftliner). Erecting the 2” (51 mm) Area Separation Wall 1. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space on both …Learn how to design and detail shaft walls made from light wood-frame buildings, such as UL U373, a single-hour single wall with a fire-resistance rating of not …UL Type Designations; Frequently Asked Questions; Acoustical Ceilings Performance Substrate; Sealant Fire Tests; Plasters - Committed To The Craft; Material Estimators Material Estimators. Sheetrock® Wallboard Estimator; Ceilings Materials Estimator; Ensemble® Acoustical Drywall Ceiling Estimator;Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-04. Please consult each listing for specific information. Hourly Rating: 2-hour. STC Rating: 65-69 STC. Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-04, cUL U373, GA ASW 0810. Sound Test Reference: RAL TL10-291.the UL Fire Resistance Directory under UL Design U373, the ULC Fire Resistance Directory ULC Design No. W312 and the WHI Fire Resistance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2x4 Wood Framing Two 1” (25.4 mm) DensGlass® Shaftliner Panels Batt Insulation UL Qualified Firestop Contractor Programs The UL Qualified Firestop Contractor Program is voluntary and allows contractors to proactively demonstrate their commitment to the proper installation of firestop systems. To learn more about fire barrier management visit this page. UL-listed systems currently deemed acceptable for use with this policy: W311, W312, W314, U336, U347, U366, U373, U375, U388. Published values for these assemblies exceed STC 60. AREA SEPARATION WALLS (ASW) FOR A ROW HOUSE WITH SECONDARY SUITES Policy B19-03We would like to show you a description here but the site won’t allow us.UL U364 Fire-Rated Assembly using ZIP System R-sheathing | UL Assembly. This UL Assembly is designed specifically as a 1-hour rating using ZIP System R-sheathing.UL U356 Assembly as Defined, in Minutes UL U356 for a lis Exterior manufacturersSide Min SPF " Fire Rated Thermo-Ply® Red or Blue attached to studs then assembly siding types applied One-hour rated assembly fire endurance from interior side only See ting of of 5/ 8 GWB that can be applied to achieve a Finish Rating of 20.4 …the UL Fire Resistance Directory under UL Design U373, the ULC Fire Resistance Directory ULC Design No. W312 and the WHI Fire Resistance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2x4 Wood Framing Two 1” (25.4 mm) DensGlass® Shaftliner Panels Batt Insulation BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ... TECHNICAL GUIDESHAFTLINER FOR AREA SEPARATION WALLSDensGlass Shaftliner Area Separation WallsFor latest information and updates: Technical Service Hotline 1.800.225.6119…The present study investigated the effect of cystathionine on astrocytoma (U373) cell proliferation, the activity of γ-cystathionase (CTH) and changes in thiols ...UL U419. Interior Partition - Steel Stud (Non-Load-Bearing) Fire Rating: 1 hours: System STC: 50 System Thickness: 5.5 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U419 on the UL website. More; Assembly Construction. Assembly Construction. Layer 1 - Gypsum Panel:• UL U370 • GA WP 3820 Figure 3. Options for fire resistance rated, wood frame wall assemblies that could be useful for shafts. Figure 2. Stair landing beam shaft wall …Fire Test Conducted in accordance with. ASTM E119. The passive fire resistance provided by fire-resistant rated gypsum based assemblies for walls, ceilings, floors, and other building systems, slows or prevents the spread of fire, allows time for evacuation, and limits fire damage. Passive fire protection measures are intended to contain a fire ...Acoustic and ire Assemblies HIGHER PERFORMANCE, HIGHER RELIABILITY, LOWER COST SOUNDPROOFING SOLUTIONS. uietRock Type gyp uietRock sound damping dryall and other acoustical products aailable rom Serious Energy Visit www.QuietRock.com or more inormation All uietRock and uietood panels are manuactured under one or more o …ETL listing means that Intertek has determined a product meets ETL Mark safety requirements.. UL listing means that Underwriters Laboratories has determined a product meets UL Mark safety requirements.UL Design U373 Area Separation Wall assembly was evaluated at a height up to 44' (13,411 mm) and the ITS/WHI GP/WA 120-04 Area Separation Wall assembly was evaluated at a height up to 68' (20,726 mm).joints stag & fin—UL Des U420—TL-76-155 52 STC*** 2-hr. shaft wall partition—3" THERMAFIBER SAFB in stud cavity—1" gypsum wallboard liner panels, set between 4" steel C-H studs 24" o.c. one side—3/4" SHEETROCK Brand gypsum panels, ULTRACODE Core, other side—panels screw att—joints stag & fin— perimeter caulked—UL Des U415 or ...SCAFCO Steel Stud Company - Steel Framing Studs and TrackBreakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-04. Please consult each listing for specific information. Hourly Rating: 2-hour. STC Rating: 65-69 STC. Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-04, cUL U373, GA ASW 0810. Sound Test Reference: RAL TL10-291.Return to results :: Keyword: "UL U373" Gypsum Board. UL Certified. DOCUMENT: CKNX.R2717 · Product Code (UL CCN): CKNX The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description). See below for more …Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States. Design Criteria and Allowable Variances Transcription . Area Separation Walls (DensGlass® Shaftliner) - GeorgiaUL Standard. Scope. Summary of Topics. Standard 515, Edition 2 Edition Date: July 17, 2015 USD $402.00-$998.00. Purchase Options Get Update Alerts. Learn more about UL's Alert Service. Digital View. Learn more about UL's Free Digital View.The Area Separation Wall assembly using DensGlass Shaftliner panels is listed in the UL Fire Resistance Directory under UL Design U373 or U375, the ULC Fire Resistance Directory ULC Design No. W312 and the Warnock Hersey Listed Product and Code Compliance Directory under WHI GP/WA 120-04. Consult the applicable fire …the UL Fire Resistance Directory under UL Design U373 or U375, the ULC Fire Resistance Directory ULC Design No. W312 and the Warnock Hersey Listed Product and Code Compliance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2” (51 mm) x 4” (102 mm) Wood Framing Standard UL 263 shall be permitted to be used to determine the hourly fire endurance rating of walls and floors with control joints. 1.11 Tests for determining the surface burning characteristics of building materials, based on the rate of flame spread, are found in the Standard for Test for Surface Burning Characteristics of Building Materials ...Title: UL Design No. L515 Author: Powers Created Date: 3/26/2007 12:28:51 PMor by email at [email protected]. This Standard can be ordered for $308.40 CAN (Hardcopy) or $257.00 CAN (PDF) from the ULC Standards website at www.ulc.ca and select ULC Standards. Once on the ULC Standards homepage, select Sales of ULC Standards Materials for further details. Yours truly, ULC STANDARDS G. Rae Dulmagethe UL fire-resistance ratings that apply to TSN products. Five of The Steel Network’s product lines are approved for use in UL® Classified Head of Wall Assemblies: VertiClip® SLD and DSLD; and VertiTrack® VTD, VTX, and VT. This library contains a list of each Head of Wall assembly that pertains to each of these TSN product lines, followed by U366, U373, U375, U388. Published values for these assemblies exceed STC 60. AREA SEPARATION WALLS (ASW) FOR A ROW HOUSE WITH SECONDARY SUITES Policy B19-03 ... UL-listed system used are not shown) Saw kerf approximately ½ depth of subfloor / roof sheathing to facilitate break-away Aluminum attachment/detachment clip …We would like to show you a description here but the site won’t allow us.joints stag & fin—UL Des U420—TL-76-155 52 STC*** 2-hr. shaft wall partition—3" THERMAFIBER SAFB in stud cavity—1" gypsum wallboard liner panels, set between 4" steel C-H studs 24" o.c. one side—3/4" SHEETROCK Brand gypsum panels, ULTRACODE Core, other side—panels screw att—joints stag & fin— perimeter caulked—UL Des U415 or ...Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. About Our Sustainability Commitment Blog Careers Contact Us Where to Buy. Tools & Documents Data Sheets Safety Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800-825-4434 ... Fiberglass Insulation. The smart choice to make spaces more comfortable and energy efficient. R-Value. The ability to resist heat flow — insulation's thermal resistance. Thermal Properties. Ability to provide thermal resistance for comfort and efficiency. Insulating for Sound. Sound absorption characteristics, helping reduce noise transmission. USG provides resources here for our UL wall assemblies for seamless integration into any construction project. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies.Dec 2, 2019 · Q: Can you explain the concept behind the wall assemblies described by UL Fire Resistance Wall Design Nos. U336, U347, U366, U373, U375 and U388? A: This series of designs is intended for use as townhouse or duplex separations as required by Sections R302.2.2 and R302.3 of the 2018 International Residential Code (IRC), and as a fire wall when ... Assemblies such as UL U336 have an option for a single wood-frame wall supporting a double shaftliner gypsum membrane. A second wood wall could be used on the other side of the double gypsum membrane to support floor framing (i.e., stair and landing framing).Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom 5/8 in. thick 4 ft wide. Gypsum board applied horizontally or vertically, unless specified below, and nailed to studs and bearing plates 7 in. OC with 6d cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam …Revit, CAD, and construction details for fire rated wall assemblies can be downloaded for planning and material estimation. About Our Sustainability Commitment Blog Careers Contact Us Where to Buy. Tools & Documents Data Sheets Safety Data Sheets FAQs Technical Support. Connect with us. Tel: 317-398-4434 Fax: 317-398-3675 Sales: 800 …5.2.2.1 UL U336 5.2.2.2 UL U347 5.2.2.3 UL U366 5.2.2.4 UL U373 5.2.2.5 UL U375 5.2.2.6 UL U388 5.2.2.7 GA ASW 0800 5.2.2.8 GA ASW 0810 5.2.2.9 GA ASW 0980 5.2.2.10 GA ASW 0985 5.2.2.11 GA ASW 0997 5.2.2.12 GA ASW 0999 5.2.2.13 GA ASW 1004 . 5. 2018 IBC Table 602 . TER 2011-01 Use of Huntsman Building Solutions Spray …•Review typical UL 263 (ASTM E119) area separation wall Designs (U336, U347, U373) •Review the tested conditions and their relevance to field conditions •Review basic end/perimeter air sealing possibilities with respect to existing approved designs •Review possibilities for air sealing the entire protected wall (as if it were an ...Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada See General Information for Fire-resistance R atings - ANSI/UL 263 Certified for United States Design Criteria and Allow able VariancesSCAFCO Steel Stud Company - Steel Framing Studs and TrackBXUV.U347 - Fire-resistance Ratings - ANSI/UL 263. 3/4" AIR SPACE CONFIGURATION A EXPOSED TO FIRE FROM AREA SEPARATION WALL SIDE ONLY. 3/4" AIR SPACE CONFIGURATION D EXPOSED TO FIRE FROM EITHER SIDE Configuration C 3/4" AIR SPACE 3/4" AIR SPACE CONFIGURATION B EXPOSED TO FIRE FROM EITHER SIDE.Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PM78. System Thickness. 16 3/32 in. CAD/Revit & Acoustics. Revit PDF. Visit UL L570 on the UL website. More. Assembly Construction.Transcription . Area Separation Walls (DensGlass® Shaftliner) - GeorgiaAs previously reported (38), expression of UL142 in U373 cells led to decreased cell-surface expression of the full-length MICA allele *001 ( Fig. 2A). How- ever, UL142 expression had no effect on ...We would like to show you a description here but the site won’t al, Return to results :: Keyword: "UL U373" Gypsum Board. UL Certified. D, Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings, the UL Fire Resistance Directory under UL Design U373, the ULC , , 8 thg 9, 2020 ... When the QR-500 or QR-510 panel is installed between the wood framing and the. UL , joints stag & fin—UL Des U420—TL-76-155 52 STC*** 2-hr. shaft wall partition—3" THERMAFI, Oct 4, 2021 · 2-Hour Fire Rating Design Reference: UL U373, UL U37, The dataset PhC-U373 contains Glioblastoma-astrocytoma U373 cell, Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-03, , Only those products bearing the UL Mark should be considered to be Ce, the UL Fire Resistance Directory under UL Design U373, the U, Oct 29, 2019 · UL Product iQ Overview. UL Product i, 2 Hour UL Listings: U347 (1-3/8” flange) 2 hour; U373 (1-1/2” flange), zOnly products which bear UL's Mark are considered as Classifi, Please let us know what you think of our products and services. ..., Only products which bear UL's Mark are considered Cer, U87, U138, U251, U343, U373, LN229, LN18 and T98G glioma cel.